13.2: Lab Technique - Polymerase Chain Reaction (PCR)
- Page ID
- 138931
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\( \newcommand{\dsum}{\displaystyle\sum\limits} \)
\( \newcommand{\dint}{\displaystyle\int\limits} \)
\( \newcommand{\dlim}{\displaystyle\lim\limits} \)
\( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)
( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\id}{\mathrm{id}}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\kernel}{\mathrm{null}\,}\)
\( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\)
\( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\)
\( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)
\( \newcommand{\vectorA}[1]{\vec{#1}} % arrow\)
\( \newcommand{\vectorAt}[1]{\vec{\text{#1}}} % arrow\)
\( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vectorC}[1]{\textbf{#1}} \)
\( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)
\( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)
\( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\(\newcommand{\longvect}{\overrightarrow}\)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\(\newcommand{\ket}[1]{\left| #1 \right>}\)
\(\newcommand{\bra}[1]{\left< #1 \right|}\)
\(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
\(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
\(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
\(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
\(\newcommand{\expect}[1]{\langle #1 \rangle}\)
\(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)
Amplifying DNA with Semi-Quantitative PCR
The protocols given below are standard semi-quantitative PCR protocols that can amplify a wide range of target DNA sizes. The first protocol outlines how to set-up a PCR reaction using a PCR "Master Mix". The second protocol sets up the PCR reaction using the individual components found in the master mix. Because a successful PCR relies upon numerous components, a few are discussed here.
Primer Design
Below is a list of characteristics that should be considered when primers are designed. Modern primer software will take these into consideration when designing primers complementary to a DNA target region. Two popular primer design sites are the NCBI Primer design tool and Primer3. Both are free to use.
- Primer length should be 15-30 nucleotides.
- Optimal G-C content of the primer should range between 40-60%.
- The 3' end of primers should contain a G or C in order to "clamp" the end of the primer to the DNA template. A G-C base pairing between a primer and its template sequence increases overall primer hybridization and PCR efficiency.
- The 3' ends of the forward and reverse primer should not be complementary to each other in order to prevent the formation of primer dimers.
- The 3' end of a single primer should not be complementary to other sequences in that prime in order to prevent the formation of hairpin loop structures.
- Optimal melting temperatures (Tm) for primers range between 52-58°C, although the range can be expanded to 45-65°C. The final Tm for both primers should differ by no more than 5°C.
- Di-nucleotide repeats (e.g., GCGCGCGCGC or ATATATATAT) or single base runs (e.g., AAAAA or CCCCC) should be avoided as they can cause polymerase "slipping" along the primed segment of DNA and or hairpin loop structures to form. If unavoidable due to nature of the DNA template, then only include repeats or single base runs with a maximum of 4 bases.
- Primer stocks will be provided as a dried pellet. The amount of DNA in each primer sample will be provided. For ease of use, add enough nuclease-free water to each dried primer pellet stock to create a stock concentration of 100 µM. Many primer companies will provide this volume.
- Dilute the primer stocks to a working stock of 10 µM. This will be diluted to 1 µM in the PCR reaction.
Materials
- Wear gloves to avoid contaminating the reaction mixtures or reagents.
- Barrier pipette tips may be used to decrease contamination of reaction mixtures and reagents.
- Include a negative control reaction in which no DNA is added, and if possible, a positive reaction.
- Set up the PCR reactions in 0.2 mL PCR tubes only. PCR tubes are thin-walled and allow for the efficient temperature changes within the reaction.
PCR Reaction Components
- Arrange all reagents needed for the PCR in a freshly filled ice bucket, and let them thaw completely on ice before setting up a reaction. Keep the reagents on ice throughout the set-up.
- Several companies sell a concentrated PCR "Master Mix" that is comprised of the Taq polymerase, a proprietary buffer at neutral pH, magnesium chloride, and DNA nucleotides (i.e., dNTPs). Common concentrations for these mixes are two-times (2X). They are diluted to 1X after setting up the PCR reaction, providing the optimal concentrations of salts, nucleotides, and Taq polymerase.
- The final concentration of MgCl2 in the reaction should be 1 mM to 1.5 mM.
- The final concentration of forward and reverse primers in the reaction should be between 0.2 and 0.4 µM (20 to 50 pmol)
- The final concentration of dNTPs in the reaction should be approximately 0.2 mM (50 µM of each dNTP). Most companies will sell a dNTP mixture containing dATP, dCTP, dGTP, and dTTP. The concentration of each dNTP in this mixture is the concentration of the mix divided by 4.
- The PCR reaction should contain 0.5 to 25 units of Taq polymerase per 50 µL reaction. Each manufacturer will sell this polymerase at a specific concentration.
- The final concentration of DNA in the reaction should range between 1.0 pg/µL to 200 ng/µL.
The PCR Workflow
The PCR workflow is outlined in Figure \(\PageIndex{1}\). This workflow is applicable whether the PCR being performed is semi-quantitative or quantitative. However, the thermocycler will be specific to semi-quantitative or quantitative protocols.
Semi-quantitative PCR Protocol
The protocols for semi-quantitative PCR given below outline the use of a PCR "Master Mix" containing Taq polymerase, buffer, magnesium chloride, and DNA nucleotides and a standard protocol using individual reagents. The Master Mix protocol uses the 2X Master Mix from Promega. Many companies sell a similar type of PCR Master Mix. Table \(\PageIndex{1}\) below provides the final concentration of each component in a 50 µL reaction volume.
| Reaction Component | Concentration | Final Concentration in 50 µL reaction volume |
|---|---|---|
| DNA | 0.1 ng/µL to 10 ng/µL | 2.0 pg/µL to 0.2 ng/µL |
| Forward Primer | 10 µM | 0.2 µM |
| Reverse Primer | 10 µM | 0.2 µM |
| 2X Master Mix |
Taq polymerase: 0.05 Units/µL dNTP mix: 1.6 mM (400 µM of each dNTP) MgCl2: 3 mM |
Taq polymerase: 0.025 Units/µL dNTP mix: 800 µM (200 µM of each dNTP) MgCl2: 1.5 mM |
The "standard" PCR protocol outlines the PCR reaction set-up using individual components. Table \(\PageIndex{2}\) below provides the final concentration of each component in a 50 µL reaction volume.
| Reaction Component | Concentration | Final Concentration in 50 µL reaction volume |
|---|---|---|
| DNA | 0.1 ng/µL to 10 ng/µL | 2.0 pg/µL to 0.2 ng/µL |
| Forward Primer | 10 µM | 0.2 µM |
| Reverse Primer | 10 µM | 0.2 µM |
| PCR buffer (without MgCl2) | 10 X | 1 X |
| MgCl2 | 50 mM | 1.5 mM |
| dNTP mixture | 10 mM (2.5 mM each of dATP, dCTP, dGTP, dTTP) | 200 µM (50 µM each of dATP, dCTP, dGTP, dTTP) |
| Taq Polymerase | manufacturer specific | 0.5 to 2.5 units |
Lab Protocol: Master Mix
- Place a PCR tube holder on ice and add the appropriate number of labeled 0.2 mL PCR tubes to the holder.
- For a 50 µL PCR reaction, add 1.0 µL of DNA sample (concentration between 0.1 ng/µL to 10 ng/µL) to each PCR reaction, except the negative control tube.
- Add 1.0 µL of 10 µM forward primer to each PCR reaction.
- Add 1.0 µL of 10 µM reverse primer to each PCR reaction.
- Add the appropriate volume of PCR master mix to dilute it to a 1X working concentration. For example, for a 2X Master Mix, add 25 µL to the reaction.
- Add enough nuclease-free water to bring each PCR reaction to 50 µL.
- Carefully mix each PCR reaction by pipetting up and down. Ensure all components are at the bottom of the tube. If necessary, flick spin to collect the contents at the bottom of the tube.
- Place the PCR tubes into the thermocycler and initiate the PCR program.
- Remove the PCR reactions when the program is complete and store them at -20°C.
Note: Design the PCR program to have a 4°C "soak" at the end of the run. The PCR reactions can be kept for several hours at this temperature.
Lab Protocol: Standard Protocol
- Place a PCR tube holder on ice and add the appropriate number of labeled 0.2 mL PCR tubes to the holder.
- For a 50 µL PCR reaction, add 1.0 µL of DNA sample (concentration between 0.1 ng/µL to 10 ng/µL) to each PCR reaction, except the negative control tube.
- Add 1.0 µL of 10 µM forward primer to each PCR reaction.
- Add 1.0 µL of 10 µM reverse primer to each PCR reaction.
- Add 5.0 µL of 10X PCR buffer to each PCR reaction. If the PCR buffer does not contain MgCl2, add 1.5 µL of 50 mM MgCl2 to each PCR reaction.
- Add 1.0 µL of a 40 mM dNTP mixture (10 mM of each nucleotide) to each PCR reaction.
- Add 1.0 µL of Taq polymerase to each PCR reaction.
- Add enough nuclease-free water to bring each PCR reaction to 50 µL.
- Carefully mix each PCR reaction by pipetting up and down. Ensure all components are at the bottom of the tube. If necessary, flick spin to collect the contents at the bottom of the tube.
- Place the PCR tubes into the thermocycler and initiate the PCR program.
- Remove the PCR reactions when the program is complete and store them at -20°C.
Note: Design the PCR program to have a 4°C "soak" at the end of the run. The PCR reactions can be kept for several hours at this temperature.
Quantitative PCR (Real-Time PCR)
The protocol given below is based on the Taqman protocol from Thermo Fisher. This protocol uses a 20X Gene Expression Mix, containing custom forward and reverse primers, in addition to a fluorescently-labelled probe that binds between these two primers. Customized Expression Mixes can be made by submitting gene sequences to the manufacturer for primer design. Alternatively, pre-designed Taqman Gene Expression mixes can be purchased from the company's extensive library of primer sequences. The Gene Expression mix is combined with a 2X Master Mix (containing buffer, nucleotides and a DNA polymerase), the cDNA for amplification and nuclease-free water for a final volume of 10 µL. The PCR reactions are set-up in optically clear 96-well plates and run in compatible real-time thermocyclers. Because 96-well plates are used, the expression of several genes can be quantified using the same plate.
Quantitative PCR Protocol
- Place a 96-well optical PCR plate on ice.
- Add 2.0 µL of cDNA sample (concentration between 1.0 pg/µL to 50 ng/µL) to each well with the exception of the negative control well.
- Add 1.0 µL of the 20X Gene Expression Mix to the appropriate wells.
- Add 10.0 µL of 2X Master Mix to each well.
- Add enough nuclease-free water to bring each PCR reaction to 20 µL.
- Cover the optical plate with the provided sealing film. Ensure all components are at the bottom of the tube. If necessary, flick spin to collect the contents at the bottom of the tube. Protect the reactions from light.
- Place the PCR tubes into the quantitative thermocycler and run the PCR program.
- 95°C for 20 seconds - 1 cycle
- 95°C for 3 seconds
- 60°C for 30 seconds
- Repeat steps 2 and 3 for 40 cycles
- Analyze the resulting quantitative data using either absolute (i.e., standard curve application) or relative (i.e. delta-delta Ct) quantitation methods.
In relative quantitation, otherwise known as the "delta-delta Ct" comparative approach, the change in gene expression in an experimental sample versus a control sample is calculated. This method requires that the Ct values for the "target" gene being studied in the experimental and control samples are first normalized, usually to a reference gene whose expression is unaffected by the experimental conditions. Examples of such reference genes are the "housekeeping genes" GAPDH, beta-actin, or 18S. To normalize, the Ct values of the reference gene are subtracted from the Ct values of the target gene (Equation #1). The normalized values between the samples are then directly compared by subtracting the normalized experimental Ct values from that of the normalized control Ct values (Equation #2). This is the change in expression or the "delta-delta" Ct. The relative fold difference in gene expression as a result of the experiment is then calculated as 2 to the power of negative delta-delta Ct (Equation #3).
1. The ΔCt value for each target gene being studied is normalized to a reference gene:
ΔCt = Cttarget gene - Ctreference gene
2. The ΔΔCt value is calculated by comparing the normalized ΔCt value of an experimental sample to the normalized ΔCt value of a control:
ΔΔCt = ΔCtexperimental - ΔCtcontrol
3. The relative fold change in expression is given by:
Fold Change = 2-ΔΔCt
In absolute quantitation, otherwise known as the "standard curve" approach, known amounts of template DNA are amplified and a standard curve is created. This standard curve is used to calculate the y-intercept and slope. These two values are then used to convert the Ct values of the gene being studied into absolute quantities.